Glossary

Actual Size: The true size of the filter. See Nominal Size

Airflow: Quantity of air passing through a filter at a stated velocity commonly measured in cubic feet per minute (CFM) or cubic meters per minute (CMM).

AMC: Airborne Molecular Contamination

Bacteria: Major groups of living organisms with simple cell structures. Many pathogens are bacteria.

Capacity: Volume of air per unit time that a clean filter can handle at a specified pressure drop 

CFM: Cubic Feet per Minute. A measurement of airflow rate. 

Cleanroom: A room with a controlled level of contamination determined by the number of particles per cubic foot 

CMM: Cubic Meters per Minute. A measurement of airflow rate. 

DOP: Dioctyl Phthalate

Downstream: The side of the filter that the air blows out of, having been filtered. 

Efficiency: A filter's ability to remove particles of a specified size from the air 

Efficiency Test: A test to determine the particle removal efficiency of a filter. A testing agent is introduced upstream. The particle concentration is measured both upstream and downstream of the filter with laser particle counters or photometer. The ratio of these measurements is the particle removal efficiency, such as 99.99%.

EPDM: Ethylene-Propylene-Diene-Monomer; a type of rubber commonly used for gaskets 

Faceguard: Screen attached to the face of a filter to protect the filter media 

FFU: Fan Filter Unit. A product that contains both a fan and a filter, or set of filters. 

FPM: Feet Per Minute. A measurement of air velocity. 

Frame: Aluminum, wood, steel, or other material into which the filter pack is inserted. 

Gasket: Rubber or sponge-like material used to prevent air leaks between the frame and its housing when they are compressed together 

Header: An extension of the frame used to hold the filter in place, and aids in creating a seal; similar to a flange 

HEPA: High Efficiency Particulate Air

IAQ: Indoor Air Quality. IAQ is concerned with the health and comfort of the air inside buildings. 

Inches of Water Gauge (in.W.G.): A measurement that indicates the amount of pressure drop in inches. 1 in.W.G. is equivalent to about  250 Pa. 

ISO: International Organization for Standardization 

m/sec: Meters per Second. A measurement of air velocity. 

Make-up Air: Unfiltered air introduced to a re-circulated air system 

Media: Filtering material. Common types of media include glass fiber, synthetic fiber, non-woven fiber, and PTFE. 

MERV: Minimum Efficiency Reporting Value 

Micron (u): One millionth of a meter 

MIL-STD: (United States) Military standard 

MSDS: Material Safety Data Sheet. Indicates the specific materials that make up a product or compound 

NAFA: National Air Filtration Association 

Neoprene: Synthetic rubber commonly used for gaskets 

Nominal Size: The size of the filter on the label, for example, 24 x 24 x 12. The actual dimensions of the filter may vary. See Actual Size 

Outgassing: The release of a gas from some material (for example, filter media) 

Particulate: Tiny particles of solid or liquid suspended in the air ranging from 1 nanometer to 100 micrometers in diameter 

Pascal (Pa): A unit that indicates the amount of pressure drop. It is the SI (International System of Units) equivalent to in.W.G. 250 Pa is approximately 1 in. W.G. 

Pressure Drop: Resistance to airflow created by an air filter. Measured in inches water gauge or Pascals. A lower pressure drop is generally preferred. 

PTFE: PolyTetraFluoroEthylene; a non-shedding, organic material used as filter media. 

Rated Airflow Volume: Specific quantity of air recommended by a filter manufacturer to be handled by a filter. (The volume of airflow at which the filter is tested) 

Re-circulated Air: Air that has been taken from a space, reconditioned (making necessary adjustments to temperature, humidity and cleanliness) and returned to the space 

SARS: Severe Acute Respiratory Syndrome. Respiratory infection which causes fever, coughing, or difficulty breathing. SARS can be fatal. 

Scan Test: Commonly called a leak test, used to find air leaks in filters. An aerosol is sprayed upstream from the filter and a laser particle counter on the downstream side is used to detect particles which signify leaks. Common aerosols used in scan tests include DOP, PSL, PAO, and Silica 

Sealant: Adhesive or other material intended to create a leak-proof seal between the pack and the frame 

Separators: Aluminum, plastic, or other material used to separate folds of pleated media to create channels for the air to flow through 

Supply Air: Air which has been conditioned and delivered to a specific space. Supply air can be 100% outside air, 100% re-circulated air, or a combination. 

UL: Underwriters Laboratory; A testing laboratory that develops standards and test procedures which are targeted towards measuring product safety 

ULPA: Ultra Low Penetration Air 

Upstream: The side of the filter that the air blows into, before being filtered.